  • Features:
  • Host and receiving probe adopt fission style to decrease contact surface of receiving probe and floor
  • Intelligent read result and automatic lock and real-time display thickness value reduce the human error and labor intensity.
  • Emission probe and receiving probe is wireless communication mode. No need to contact any wire.
  • Nondestructive testing of double surfaces. Floor does not need any treatment. No need coupling agent.
  • High test speed. Average 3 minutes could test 3-5 test points.

Floor Slab Thickness Gauge Meter Nonmetallic Material Thickness Gauge for Wall Beam Pillar Lumber Ceramic

Features:

1. Host and receiving probe adopt fission style to decrease contact surface of receiving probe and floor

2. Intelligent read result and automatic lock and real-time display thickness value reduce the human error and labor intensity.

3. Emission probe and receiving probe is wireless communication mode. No need to contact any wire.

4. Nondestructive testing of double surfaces. Floor does not need any treatment. No need coupling agent.

5. High test speed. Average 3 minutes could test 3-5 test points.

6. High test precision. Instrument provides data to guide to aim at the probe.

7. Thickness display directly. No need analysis conversion. The results can be stored and printed.

Work environment condition:

Ambient temperature:-10C — +40C(Avoid long time sun direct explosion)

Relative humidity (RH)

Electromagnetic interference (EMI)

No strong alternating electromagnetic field

Specification:

1 Test scope : 40mm~800mm

2 Permissible error : 40 ~ 600 mm ±1 mm

3 601~ 800 mm ±2 mm

4 Data storage capacity : 3.2 group data

5 Operational environment:

6 Temperature:-10℃~+40℃

7 Dampness: <90%RH

8 EMI: no strong electromagnetic field

9 work more than 30 hours

View full details