VTSYIQI Laboratory Turbidity Meter Multiparameter Turbidimeter with 7 Point Calibration Range 0 to 2000 NTU/FNU 0 to 500 EBC 0 to 9999 ASBC Accuracy ±2% 4 PCS Calibration Solution

VTSYIQI Laboratory Turbidity Meter Multiparameter Turbidimeter with 7 Point Calibration Range 0 to 2000 NTU/FNU 0 to 500 EBC 0 to 9999 ASBC Accuracy ±2% 4 PCS Calibration Solution

Regular price $1,030.00 USD
Regular price Sale price $1,030.00 USD
Sale Sold out
Shipping calculated at checkout.

VTSYIQI Laboratory Turbidity Meter Multiparameter Turbidimeter with 7 Point Calibration Range 0 to 2000 NTU/FNU 0 to 500 EBC 0 to 9999 ASBC Accuracy ±2% 4 PCS Calibration Solution

About this item:

2 to 7 points push-button calibration using the formazin standards.

Selectable 4 turbidity units, including the NTU, FNU, EBC and ASBC.

TSS conversion factor ensures accurate measurement of the total suspended solids.

Continuous measurement mode can be used for indexing and matching the sample vials.

Hold freezes current reading for easy viewing and recording.

Features:

2 to 7 points push-button calibration using the formazin standards.

Selectable 4 turbidity units, including the NTU, FNU, EBC and ASBC.

TSS conversion factor ensures accurate measurement of the total suspended solids.

Continuous measurement mode can be used for indexing and matching the sample vials.
Hold freezes current reading for easy viewing and recording.

Password protection prevents the unauthorized calibration and settings.

Setup menu allows setting the 9 parameters, including the date and time, measurement mode, resolution, backlight brightness, etc.

Expanded memory stores and recalls up to 200 data sets.

Stored readings can be transferred into the computer by USB communication interface.

Reset feature automatically resumes all settings back to factory default options.

Meter Includes:

Sample vials, calibration standards (0.02, 200, 500 and 1000NTU)

lint-free cloth and power adapter

Specification:

Measurement Method:ISO 7027 nephelometric method (90°)

Turbidity Range:0~2000 NTU/FNU, 0~500 EBC, 0~9999 ASBC

Total Suspended Solids Range:Deponds on TSS factor setting

Resolution:0.01 (0~100 NTU), 0.1 (100~999 NTU), 1 (999~2000 NTU)

Accuracy:±2% (0~500 NTU), ±3% (501~2000 NTU)

Calibration Points:2~7 points (0.02, 10.00, 200, 500, 1000, 1500, 2000 NTU)

Light Source:Infrared-emitting diode (850nm wavelength)

Detector:Silicon Photodiode

Stray Light:<0.02 NTU

Sample Vials:60(H)×25(Dia)mm

Memory:Stores up to 200 data sets

Output:USB communication interface

Display:4.5 inch TFT LCD

Power Requirements:DC12V / 2A power adapter

Dimensions:250(L)×177(W)×96(H)mm

Weight:1.2kg