VTSYIQI
VTSYIQI Oxygen Gas Detector O2 Gas Monitor O2 Gas Leak Alarm with Measuring Range 0 to 30% VOL Resolution Ratio 0.1% vol Detection Method Natural Diffusion for Petroleum Industry Gas Detection
VTSYIQI Oxygen Gas Detector O2 Gas Monitor O2 Gas Leak Alarm with Measuring Range 0 to 30% VOL Resolution Ratio 0.1% vol Detection Method Natural Diffusion for Petroleum Industry Gas Detection
VTSYIQI Oxygen Gas Detector O2 Gas Monitor O2 Gas Leak Alarm with Measuring Range 0 to 30% VOL Resolution Ratio 0.1% vol Detection Method Natural Diffusion for Petroleum Industry Gas Detection
About this item:
Detection gas:Oxygen O2;Measuring Range:0-30%VOL;Optional Range:0-30%、0-100%VOL;Resolution Ratio:0.1%vol
Back lighting:backlight turns on automatically in dark environment and alarming situation. You can also turn on by press the backlight button
Low alarm point and high alarm point adjustable;Audible alarm:up to 95 dB pulse output at 0.25 meter from the detector
It is the single gas detector with diffusion detection method, it adopts silicone rubber technology and ergonomic design, ithas simple operation menu, and do not need to replace battery. It is waterproof and dust proof, with replaceable gas sensor module, lithium battery. For this device, its detecting data can be uploaded directly to the computer to view.
The portable gas detector has a wide range of applications in metallurgy, petrochemicals, municipal services, paper-making, fire and other fields.
Technical Parameters:
Detection gas:Oxygen O2
Measuring Range:0-30%VOL
Optional Range:0-30%、0-100%VOL
Resolution Ratio:0.1%vol
Detection principle:Semiconductor/catalysis/electrochemistry
Display:LCD digital display of gas type /gas concentration/ status
Case:Rugged, shockproof synthetic rubber
Battery:3.7v 1300mA rechargeable lithium battery
Relative humidity:5-95% RH (non-condensing)
Operating temperature :-40°C to 50°C
Calibration:automatic calibration and return to zero
Back lighting:backlight turns on automatically in dark environment and alarming situation. You can also turn on by press the backlight button
Self-test:full self test function when start-up
Alarm indication:clearly audible and visual way to indicate the alarm level
Audible alarm:up to 95 dB pulse output at 0.25 meter from the detector
Visual alarm:blinking, wide-angle alarm lens and 2 red alarm LED and alarming LCD readings
Other alarms:low battery; turn off warning; sensor malfunction, over range.
Detection accuracy:3% FS
Interface Definition:U3 port (USB)
Storage capacity:MAX 6000 records
Appearance Size:(length 100 * width 65 * height 28) mm
Weight:220g
Explosion-proof mark:Ex ib IIB T3 Gb
Explosion-proof certificate number:CNEx19.5062X