Skip to product information
1 of 11

VTSYIQI Ultrasonic Flow Meter Ultrasonic Water Flow Meter With TS-2 Transducer Measuring Range DN15 to 100mm 0.59 to 3.93in

VTSYIQI Ultrasonic Flow Meter Ultrasonic Water Flow Meter With TS-2 Transducer Measuring Range DN15 to 100mm 0.59 to 3.93in

Regular price $965.00 USD
Regular price Sale price $965.00 USD
Sale Sold out
Shipping calculated at checkout.
Feature
Items: Performance and Parameter
Main Unit:
Principle: transit-time ultrasonic flowmeter
Accuracy: Accuracy :over 1%-2%; Repeatability: over 0.2%
Display :4 line x 16 character LCD with backlight
Dimension: 200*93*33cm: 390g
Operation: Support 16 key light touch keyboard and the Simulation keyboard software
Data interface:
Insulate RS232 serial interface, upgrade the flew meter software by computer,
support the MODBUS, etc.
Signal Output: 1 way OCT output
Special Cable :
Twisted-pair cable, ;Select the RS232 communication.;
Generally, the standard is 5m*2, optional 10m*2
Pipe Condition :
Pipe Material :
Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass
steel product, liner is allowed.
Pipe Diameter :DN 15---100mm
Straight length pipe:
Transducer installation should be satisfied: upstream10D, downstream 5D,
30D from the pump.
Measuring Medium:
Type of Liquid :Water ; Ultra-pure liquids; Solvents and other liquids
Temperature: Standard Transducer: -40--90℃; High-temperature transducer: -40--160℃
Turbidity: under 10000ppm and less bubble
Flow rate :0--±10m/s
Flow Direction :Measuring two (plus-minis) direction of flow rate
Working Environment:
Temperature:
Main Unit: -20--60℃
Flow transducer: -40--160℃;
Temperature transducer: according to the customer’s demands.
Humidity: Main Unit: 85% RH
Power Supply: AC 110V-240V
View full details