VTSYIQI Benchtop Turbidimeter Kit Digital Nephelometer Turbidity Meters with TSS Measurement Mode Range 0~2000 NTU/FNU 0~500 EBC 0~9999 ASBC 4 PCS Turbidity Standard Solutions 7 Point Calibration

VTSYIQI Benchtop Turbidimeter Kit Digital Nephelometer Turbidity Meters with TSS Measurement Mode Range 0~2000 NTU/FNU 0~500 EBC 0~9999 ASBC 4 PCS Turbidity Standard Solutions 7 Point Calibration

常规价格 $1,030.00 USD
常规价格 促销价 $1,030.00 USD
销售额 售罄
结账时计算的运费

VTSYIQI Benchtop Turbidimeter Kit Digital Nephelometer Turbidity Meters with TSS Measurement Mode Range 0~2000 NTU/FNU 0~500 EBC 0~9999 ASBC 4 PCS Turbidity Standard Solutions 7 Point Calibration

About this item:

2 to 7 points push-button calibration using the formazin standards.

Selectable 4 turbidity units, including the NTU, FNU, EBC and ASBC.

TSS conversion factor ensures accurate measurement of the total suspended solids.

Continuous measurement mode can be used for indexing and matching the sample vials.

Hold freezes current reading for easy viewing and recording.

Features:

2 to 7 points push-button calibration using the formazin standards.

Selectable 4 turbidity units, including the NTU, FNU, EBC and ASBC.

TSS conversion factor ensures accurate measurement of the total suspended solids.

Continuous measurement mode can be used for indexing and matching the sample vials.

Hold freezes current reading for easy viewing and recording.

Password protection prevents the unauthorized calibration and settings.

Setup menu allows setting the 9 parameters, including the date and time, measurement mode, resolution, backlight brightness, etc.

Expanded memory stores and recalls up to 200 data sets.

Stored readings can be transferred into the computer by USB communication interface.

Reset feature automatically resumes all settings back to factory default options.

Meter Includes:

Sample vials, calibration standards (0.02, 200, 500 and 1000NTU)

lint-free cloth and power adapter

Specification:

Measurement Method:ISO 7027 nephelometric method (90°)

Turbidity Range:0~2000 NTU/FNU, 0~500 EBC, 0~9999 ASBC

Total Suspended Solids Range:Deponds on TSS factor setting

Resolution:0.01 (0~100 NTU), 0.1 (100~999 NTU), 1 (999~2000 NTU)

Accuracy:±2% (0~500 NTU), ±3% (501~2000 NTU)

Calibration Points:2~7 points (0.02, 10.00, 200, 500, 1000, 1500, 2000 NTU)

Light Source:Infrared-emitting diode (850nm wavelength)

Detector:Silicon Photodiode

Stray Light:<0.02 NTU

Sample Vials:60(H)×25(Dia)mm

Memory:Stores up to 200 data sets

Output:USB communication interface

Display:4.5 inch TFT LCD

Power Requirements:DC12V / 2A power adapter

Dimensions:250(L)×177(W)×96(H)mm

Weight:1.2kg