VTSYIQI Portable Chlorophyll Meter Chlorophyll Temperature Nitrogen Moisture Meter Gauge 4 In 1 Plant Nutrition Tester Nitro Demand Detector with Measuring Range Chlorophyll 0.0 to 199.9 SPAD Leaf Temperature Range0 to 60Celsius
VTSYIQI Portable Chlorophyll Meter Chlorophyll Temperature Nitrogen Moisture Meter Gauge 4 In 1 Plant Nutrition Tester Nitro Demand Detector with Measuring Range Chlorophyll 0.0 to 199.9 SPAD Leaf Temperature Range0 to 60Celsius
VTSYIQI Chlorophyll Temperature Nitrogen Moisture Meter Gauge 4 In 1 Plant Nutrition Tester Nitro Demand Detector with Measuring Range Chlorophyll 0.0 to 199.9 SPAD Leaf Temperature Range0 to 60Celsius
Feature
Be able to save chlorophyll, nitrogen, leaf temperature and leaf humidity at the same time
Two LED light sources emit two kinds of light, one is red light (peak wavelength is 650m), and the other is infrared light (940nm)
The instrument is small, portable and easy to handle with one hand
Non-destructive measurement, it can quickly and non-destructively detect plants, without damaging crop growth
Large data storage capacity, using SD card storage, easy to read data, storage capacity up to 2GB, data be export to PC in excel format for further analysis
Product Introduction
▷The chlorophyll meter is able to measure the relative content of chlorophyll in plant leaves (unit SPAD) or “greenness”, thereby learning plants’ actual demands on nitryl and helping the user identify the shortage of nitryl in soil or whether nitrogenous fertilizer has been applied excessively. This meter can be used to enhance the utilization ratio of nitrogenous fertilizer and protect the environment.
Major Technical Indicators
1. Measurement object: terrestrial plant leaves
2. Measurement parameters: chlorophyll and leaf temperature, humidity, nitrogen
Nitrogen range:Full
Nitrogen accuracy:±5%
Chlorophyll range:0.0-199.9 SPAD
Chlorophyll accuracy:±1SPAD
Leaf temperature range:0-60℃
Leaf temperature accuracy ±1℃
Moisture range 0-5g/cm²
Moisture accuracy ±3%
3. Measurement principle: optical density difference at two wavelengths of 650nm and 940nm
4. Measuring range: 0.0-199.9 SPAD
5. Measuring area: 2mm*3mm
6. Measurement accuracy: within ±1.0 SPAD units (at room temperature, the SPAD value is between 0-50)
7. Repeatability: Within ±0.3 SPAD units (SPAD values between 0-50, keep the measurement position unchanged)
8. Measurement time interval: less than 2 seconds
9. Memory: 16GB of memory, can calculate/display average values, and remove outliers
10. Maximum sample thickness: 1 mm
11. Sample insertion depth: 10 mm
12. Power supply: 4.2V rechargeable lithium battery
13. Battery capacity: 2000 mAh
14. Weight: 250g
15. Dimensions: 140×85×45mm (length×width×height)