VTSYIQI Hazemeter Lab Hazemeter Light Transmission Meter 21mm Aperture for Glass Plasic
VTSYIQI Hazemeter Lab Hazemeter Light Transmission Meter 21mm Aperture for Glass Plasic
VTSYIQI Hazemeter Lab Hazemeter Light Transmission Meter 21mm Aperture for Glass Plasic
Feature:
1). It conforms to international standards GB/T 2410, ASTM D1003/D1044 and with a calibration certification from a third party laboratory.
2). No need to do warm-up, after instrument is calibrated, it can be used. And measurement time is only 1.5 seconds.
3). Three kinds of illuminants A,C and D65 for haze and total transmittance measurement.
4). 21mm test aperture.
5). Open measurement area, no limit on sample size.
InstrumentAdvantages
1).It conforms to both ASTM and ISO international standards ASTM D 1003,ISO13468,ISO 14782, JIS K 7361 and JIS K 7136.
2). Instrumentis with a calibration certification from a third party laboratory.
3). Noneed to do warm-up, after instrument is calibrated, it can be used. Andmeasurement time is only 1.5 seconds.
4). Threekinds of illuminants A,Cand D65 for haze and total transmittance measurement.
5). 21mm testaperture.
6). Openmeasurement area, no limit on sample size.
7). Itcan realize both horizontal and vertical measurement to measure different kindsof materials such assheets, film, liquid, etc.
8). Itadopts LED light source whose lifetime can reach 10 years.
Technical Data
Character:ASTMD1003/D1044and ISO13468/ISO1478 standard for haze measurement and light transmittancemeasurement.
Openmeasurement area and samples can be tested vertically and horizontally.Application: glass, plastic, film, display screen, packaging and otherindustries.
Illuminants:D65,A,C
Standards:ASTMD1003/D1044, ISO13468/ISO14782, GB/T 2410,JJF 1303-2011, CIE 15.2, GB/T3978,ASTM E308, JIS K7105, JIS K7361, JIS K 7136
Test Parameter:ASTMand ISO (HAZE),Transmittance (T)
TestAperture:21mm
InstrumentScreen:5inches color LCD screen
Haze Repeatability:Φ21mmaperture, Standard Deviation: within 0.08(when a haze standard with value 40is measured 30 times at 5-second interval after calibration)
Transmittance Repeatability:≤0.1unit
Geometry:Transmittance0/D (0 degree illumination, diffused receiving)
Integrating Sphere Size:Φ154mm
LightSource:400~700nmfull spectrum LED light source
Test Range:0-100%
Haze Resolution:0.01unit
Transmittance Resolution:0.01 unit
Sample Size:Openspace, no size limit
Data Storage:20,000pcs of samples
Interface:USB
Power Supply:DC12V(110-240V)
Working Temperature:+10 –40 °C (+50 – 104 °F)
Storage Temperture:0 – 50°C (+32 – 122 °F)
Size:L x Wx H: 310mmX215mmX540mm
Model: Digital Display Push-pull Force Meter
Maximum load value: 500N; 50kg; 110Lb; 1800Oz
Load division value:0.1N; 0.01kg; 0.01Lb; 1Oz
Sensor structure: Inner sensor
Accuracy: ±1%
查看完整详细信息