VTSYIQI
VTSYIQI NH3 Gas Detector Portable NH3 Gas Detector with Measuring Range 0-200ppm Sound & Light Alarm Resolution 0.1ppm Standard 4-20mA and RS485 Output Infrared Remote Control
VTSYIQI NH3 Gas Detector Portable NH3 Gas Detector with Measuring Range 0-200ppm Sound & Light Alarm Resolution 0.1ppm Standard 4-20mA and RS485 Output Infrared Remote Control
VTSYIQI NH3 Gas Detector Portable NH3 Gas Detector with Measuring Range 0-200ppm Sound & Light Alarm Resolution 0.1ppm Standard 4-20mA and RS485 Output Infrared Remote Control
Feature:
Detection gas: Ammonia; Range: 0-200ppm; Resolution: 0.1ppm
Adopt the original Swiss imported sensors
Three-wire 4-20mA analogue and RS485 signal outputs as standard
Infrared remote control can be remote non-open cover to achieve the alarm point setting, zero calibration, modify the address and other functions.
Monitoring the gas concentration in the environment or pipeline, full software auto-calibration function, zero calibration function, make gas monitoring more accurate and reliable.
Product overview:
Adopt the original Swiss imported sensors
Three-wire 4-20mA analogue and RS485 signal outputs as standard
Compatible with a variety of control alarms, PLC, DCS and other control systems, remote monitoring can be realised.
Explosion-proof design, fast, reliable and stable; explosion-proof grade Ex d II CT6
Full software auto-calibration function, the machine is equipped with standard three keys to achieve single person single point on-site maintenance.
Monitoring the gas concentration in the environment or pipeline, full software auto-calibration function, zero calibration function, make gas monitoring more accurate and reliable.
With temperature compensation, it can perfectly realise the compensation of gas concentration under different ambient temperatures.
Infrared remote control can be remote non-open cover to achieve the alarm point setting, zero calibration, modify the address and other functions.
One or two switching signals can be output to drive external devices such as exhaust fans or solenoid valves.
Specifications:
Detection gas: NH3 Ammonia
Detection Principle: Electrochemical principles
Measuring range: 0-200ppm; Resolution: 0.1ppm; Accuracy: ±5% F.S or ±10% (depending on specific gas type)
Response time: ≤60S
Output Signal: 4-20mA and RS485 Output
Repeatability: ≤±1%
Zero drift: ≤±1%
Operating Temperature: G1/2 male thread explosion-proof hose
Explosion-proof grade: Ex d II CT6
Power supply: 12-24V DC
Dimension: 180×150×90mm
Recovery Time: ≤10S
Linearity Error: ≤±1%
Display Technology: High brightness digital tube display
Pipe Thread Size: M45*2mm
Operating humidity: 0-95%RH
Protection class: IP65
Working time: 24hours
Weight: ≤1.6kg