跳至产品信息
1 / 7

VTSYIQI

VTSYIQI Ultrasonic Durometer Ultrasonic Hardness Meter Tester Gauge With Test Force 19.6N Maximum Test Surface Roughness Ra<5μm 2kgf Manual Probe HV50~1599 HRC20~68 HB85~650 Accuracy ±4% HV ±4% HB ±1.5HR USB Interface

VTSYIQI Ultrasonic Durometer Ultrasonic Hardness Meter Tester Gauge With Test Force 19.6N Maximum Test Surface Roughness Ra<5μm 2kgf Manual Probe HV50~1599 HRC20~68 HB85~650 Accuracy ±4% HV ±4% HB ±1.5HR USB Interface

常规价格 $2,380.00 USD
常规价格 促销价 $2,380.00 USD
销售额 售罄
结账时计算的运费

Ultrasonic Durometer Ultrasonic Hardness Meter Tester Gauge With Test Force 19.6N Maximum Test Surface Roughness Ra<5μm 2kgf Manual Probe HV50~1599 HRC20~68 HB85~650 Accuracy ±4% HV ±4% HB ±1.5HR USB Interface

Feature:

Directly test Vickers hardness value of workpiece, and there is no need to convert like Leeb or Shore hardness tester. The conversion error is eliminated.

High test speed -- output test results within seconds

Standard Vickers indentation, tiny indentation, little damage to the workpiece

The test results are related to the elastic constants of the workpiece. New workpiece needs to be calibrated according to the elastic constants.

Small volume, light weight and easy to carry.

Easy to test on assembly line.

It can be used for testing on site and testing large workpiece and can be used to make hardness measurements on positions difficult to access, such as tooth flanks or roots of gears.

Only measuring the hardness condition of the surface contacted

The development of microcontroller technology makes it easy to calibrate workpiece with different elastic constants.

Characteristics:

Directly test Vickers hardness value of workpiece, and there is no need to convert like Leeb or Shore hardness tester. The conversion error is eliminated.

High test speed -- output test results within seconds

Standard Vickers indentation, tiny indentation, little damage to the workpiece

The test results are related to the elastic constants of the workpiece. New workpiece needs to be calibrated according to the elastic constants.

Small volume, light weight and easy to carry.

Easy to test on assembly line.

It can be used for testing on site and testing large workpiece and can be used to make hardness measurements on positions difficult to access, such as tooth flanks or roots of gears.

Only measuring the hardness condition of the surface contacted

The development of microcontroller technology makes it easy to calibrate workpiece with different elastic constants.

Probe Specification:

Probe:5kgf manual probe

Test force:49N

Diameter:22mm

Length:150mm

Resonating rod diameter:2.4mm

Maximum roughness of test surface:Ra<10μm

Minimum workpiece weight:0.3kg

Minimum workpiece thickness:2mm

Application:Groove, tooth flanks, roots of gears

Technical Specification:

Main hardness scale: HV ;Convertible hardness scale: HRC, HRA, HRB, HBW

In multi-points calibration mode, any hardness scales can be chosen.

Testing range: HV50~1599, HRC20~68, HB85~650

Test direction:Support 360° test, as long as the angle between the indenter and the surface doesn’t exceed 90° ± 3°.

Battery: 3.6V, 3000mAh lithium battery

Endurance: 10 hours

Test data can be exported to computer terminal.

Norms: GB/T 34205-2017; DIN 50159-1-2008; ASTM-A1038-2005; JB/T 9377-2010; JJF 1436-2013.

High accuracy----±4%HV, ±4%HB, ±1.5HR.

Tiny test indentation---- requires a high-power microscope to see.

Little damage to the workpiece.

High test speed----output test results in 1s at the soonest.

New appearance design, innovative sculpt, convenient to hold and good craft.

Full English display, menu-type operation, few keys, simple and convenient to operate.

3.5 inches large LCD screen with 320×480 color graphics dot matrix, beautiful font and graphics, rich information and clear display.

Directly display the current measured value, cumulative measured value, maximum value, minimum value, average value and conversion value.

50 sets of data storage.

Simple calibration----5 sets of one-block calibration data, 1 set of default calibration data and 5 sets of multi-blockss calibration data can be stored in the host.

For materials with different elastic constants, just an one-block calibration is required to adapt to the new material.

For unknown material or material without conversion table, the hardness scale can be arbitrarily selected for multi-points calibration to eliminate the systematic error brought by the conversion table.

Easy to test on assembly line.

查看完整详细信息

Video