VTSYIQI
VTSYIQI Benchtop Color Meters Benchtop Spectrophotometer Benchtop Colorimeter with Wavelength Range 400nm-700nm Reflectance Resolution 0.01% Measuring Aperture Φ10mm for Color Measurement of Glass and Liquid
VTSYIQI Benchtop Color Meters Benchtop Spectrophotometer Benchtop Colorimeter with Wavelength Range 400nm-700nm Reflectance Resolution 0.01% Measuring Aperture Φ10mm for Color Measurement of Glass and Liquid
VTSYIQI Benchtop Color Meters Benchtop Spectrophotometer Benchtop Colorimeter with Wavelength Range 400nm-700nm Reflectance Resolution 0.01% Measuring Aperture Φ10mm for Color Measurement of Glass and Liquid
Introduction:
Our transmission type liquid spectrophotometer is a high performance spectrometer specially designed for measuring liquid transmittance, absorbance, concentration, chromaticity and other parameters. The instrument adopts D/0 measurement structure and integrates technologies such as full-band light source, single grating optical path spectroscopy system and other real-time calibrations, so that the resolution of the instrument reaches 0.0001, the standard deviation of transmittance is within 0.08%, and the chromaticity value: ΔE*ab 0.015.
D / 0 structure is adopted
Suitable for liquid and glass color measurement
Platinum, cobalt and Gardner index -- characterization of liquid yellow degree
Feature:
Illumination:Illumination: d/0 (diffused Illumination, 0 degree viewing) (conform to CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7, JIS Z8722 Condition C standard)
Integrating sphere:Φ 40mm, avian-d fully diffuse surface coating
Lighting source:CLEDs(Full band balanced LED light source)
Sensor:Dual optical path sensor array sensor
Wavelength range:400nm-700nm
Wavelength interval:10nm
Half band width:5nm
Test range:0-200%
Reflectance Resolution:0.01%
Observer angle:2°/10°
Illuminants:A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CMF,U30,DLF,NBF,TL83,TL84
Data being displayed:Transmittance graph/value, chromatic value, color difference values, color assessment results, color tendency, history color value simulation, manual input standard sample, generate measurement reports
Measurement interval:1S
Measurement time:1S
Measuring aperture:Φ10mm
Color space:CIELab,LCh,CIELuv,XYZ,Yxy,transmissivity,HunterLabMunsell,MI,CMYK
Color difference formula:ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00
Other indices:
WI(ASTME313-00,ASTME313-73,CIE/ISO,Hunter,Taube Berger Stensby),
YI(ASTMD1925,ASTME313-00,ASTME313-73),Tint(ASTME313-00),Isomorphism index milm,color fastness, color fastness, APHA, Pt Co, Gardner, Saybolt, astmcolor, Saybolt, ASTM Color
Repeatability:Transmittance, standard deviation within 0.08% Chromaticity value: ΔE*ab 0.015 (When measuring air 30 x at 5-second intervals after air calibration), max. 0.03
Inter station difference:ΔE*ab less than ≤0.2
Data interface:USB
Store data:Mass storage (PC)
Light source lifetime:5 years, 1.5 million tests
Size:475*340*150mm(L*W*H)
Weight:About 7kg
Operating temperature:0 ~ 45 ℃, relative humidity 80% or lower (at 35 ° C), no water vapor condensation
Storage temperature:-25 ° C to 55 ° C, relative humidity 80% or less (at 35 ° C), no moisture condensation
Standard accessories:Power line, color management software, driver software, data line, black correction board, 40 * 10mm, cuvette
Optional Accessories:40 * 33mm cuvette (for ASTM color), 40 * 100mm cuvette (measuring Saybolt)