Skip to product information
1 of 5

VTSYIQI Portable pH Conductivity Dissolved Oxygen Meter With Accuracy ±0.002 pH Automatic temperature compensation USB For measuring pH oxidation reduction potential ion concentration conductivity salinity resistivity and dissolved oxygen

VTSYIQI Portable pH Conductivity Dissolved Oxygen Meter With Accuracy ±0.002 pH Automatic temperature compensation USB For measuring pH oxidation reduction potential ion concentration conductivity salinity resistivity and dissolved oxygen

Regular price $1,050.00 USD
Regular price Sale price $1,050.00 USD
Sale Sold out
Shipping calculated at checkout.

Portable pH/Conductivity/Dissolved Oxygen Meter

Multiparameter portable pH meter, suitable for measuring pH, oxidation reduction potential, ion concentration, conductivity, total dissolved solids, salinity, resistivity and dissolved oxygen.

pH Mode:
• Multiparameter water quality meter is equipped with a backlit LCD display.
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic electrode diagnosis shows the pH slope and zero offset.

ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes ensure the reliable ORP measurements.

Ion Concentration Mode:
• 2 to 5 points calibration, including the selection of 8 concentration points.
• Automatic electrode diagnosis shows the calibration points and slopes.
• Direct ion concentration readout simplifies the measurement process.
• Selectable concentration units (ppm, mg/L, mol/L) and ionic valency.

Conductivity/TDS/Salinity/Resistivity Modes:
• 1 to 5 points calibration with automatic recognition for conductivity standards.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear and
  pure water compensations, seawater and practical salinity measurement modes.

Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Salinity and barometric pressure compensations eliminate the measurement errors.

Other Features:
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-read function senses and locks the measurement endpoint.
• Calibration due alarm reminds the user to calibrate the meter regularly.
• Auto-power off effectively conserves battery life.
• Setup menu allows setting the number of calibration points, stability criteria, temperature unit,
  date and time, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface is easy to transfer data to a PC.
• Multi-mode power scheme (batteries, power adapter, USB port) ensures the smooth operation of the meter.

 

Specifications:

pH
Range:-2.000 to 20.000 pH
Resolution:0.001 / 0.01 / 0.1 pH, selectable
Accuracy:±0.002 pH
Calibration:1 to 5 points
pH Buffer Options:USA / NIST / DIN / 2 custom buffers

ORP
Range:-1999.9 to 1999.9 mV
Resolution:0.1 / 1 mV, selectable
Accuracy:±0.2 mV
Measurement Modes:Relative / Absolute mV

Ion Concentration
Range:0.00 to 19999 (depending on the range of ISE)
Resolution:0.001, 0.01, 0.1, 1, automatic
Accuracy:±0.5% F.S. (monovalent), ±1% F.S. (divalent)
Calibration:2 to 5 points
Calibration Solutions:0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000
Measurement Units:ppm, mg/L, mol/L, mmol/L

Conductivity
Range:0 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Resolution:0.001, 0.01, 0.1, 1, automatic
Accuracy:±0.5% F.S.
Calibration:1 to 5 points
Calibration Solutions:10 µS / 84 µS / 1413 µS / 12.88 mS / 111.8 mS
Temperature Coefficient:0.0 to 10.0%/°C
Pure Water Compensation:Yes
Reference Temperature:20 / 25°C
Cell Constant:K=0.1 / 1 / 10 / Custom

TDS
Range:0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt
Resolution:0.01, 0.1, 1, automatic
Accuracy:±1% F.S.
TDS Conversion Factor:0.1 to 1.0 (default 0.5)

Salinity
Range:0.00 to 80.00 ppt / 0.00 to 42.00 psu
Resolution:0.01
Accuracy:±1% F.S.

Resistivity
Range:0.00 to 20.00 MΩ
Resolution:0.01
Accuracy:±1% F.S.

Dissolved Oxygen
Range:0.00 to 20.00 mg/L / 0.0 to 200.0 % saturation
Resolution:0.01 / 0.1, selectable
Accuracy:±0.2 mg/L / ±2.0 %
Calibration:1 or 2 points
Pressure Correction:60.0 to 112.5 kPa / 450 to 850 mmHg, manual
Salinity Correction:0.0 to 50.0 g/L, manual

Temperature
Range:0 to 105°C / 32 to 221°F
Resolution:0.1°C/°F
Accuracy:±0.5°C / ±0.9°F
Calibration:1 point
Calibration Range:Reading ±10°C/°F

Other Specifications
Temperature Compensation:0 to 100°C / 32 to 212°F, manual or automatic
Hold Function:Manual / Auto-read measurement endpoint
Stability Criteria:Low / High
Calibration Due Alarm:1 to 31 days or off
Auto-Power Off:10 / 20 / 30 minutes after last key pressed
Memory:Stores up to 500 data sets
Output:USB communication interface
Connector:BNC, 6-pin mini-DIN, 3.5 mm jack socket
Display:Custom LCD (80 × 60 mm)
Power Supply:3 × 1.5V AA batteries or 5V DC power adapter
Environmental Conditions:0 to 50°C / 32 to 122°F, relative humidity < 80%
Dimensions:170 × 85 × 30 mm
Weight:300 g

View full details